Table Top Flow Setup |
Table Top Level Setup |
|
|
ASI-11001 |
-
Piezo resistive transducer for strain measuremet.
-
Micrometer 0-20mm (Accuracy 0.01mm) for strain generation.
-
Strain gauges mounted on cantilever in hal & full Wheatstone bridge and instrumentation amplifier with Zero & spanadjustment for calibration
-
Experiments on Gauge factor determination, Strain indicator, Displacement measurement using Strain gauges.
|
|
ASI-11002 |
-
Micrometer 0-20mm (Accuracy0.01mm)
-
Precision phase sensitive rectifier
-
Measurement frequency of 1 KHz sine.
-
Zero & span adjustment for calibration of following transducers
|
|
i) Resistive linear transducer |
0-20mm |
|
ii) Capactivie linear transducer |
0-20 mm |
|
iii) Capacitive angular transducer |
0-90degree |
|
iv) Inductive linear transducer |
0-20mm |
|
v) LVDT transducer |
0-20mm or (-10 to+10mm) |
|
|
ASI-11003 |
-
12V DC motor with peed varying from0-4000rpm & rotating lotted wheel having 8 lots,
-
Individual signal conditioning circuit with programmable threshold comparator.
-
F to V Converter with span & zero amplifier.
-
Speed transducers:
|
| |
i) Magnetic pickup |
| |
ii) Photo reflective |
| |
iii) Photo interruptive |
| |
iv) Inductive pickup with envelop detector. |
| |
v) Stroboscope |
| |
vi) Hall sensor |
|
|
ASI-11004 |
-
40KHz gated oscillator to generate Ultrasonic sound waves.
-
V to I function block to convert voltage O/P into 4 to 20m A current loop
-
Sound Sensors:
i) Ultrasonic Distance Measuremet.
ii) Dynamic microphone as Sound/ Audio sensor
|
|
ASI-11005 |
-
Instrumentation Amplifier to amplify thermocouple signals
-
Built in heart bar/mini oven driven by Powr Aplifier of sufficient wattage.
-
Temp. Selection upto 95 degree C in 5 ranges with ON/OFF closed loop control.
|
| |
Temp. sensors: |
| |
i) Thermocouple J with room temp. calibration pot. |
| |
ii) Thermocouple K with room temp. calibration pot. |
| |
iii) Thermister (100K). |
| |
iv) PT100, |
| |
v) IC sensor (AD 590) vi) Bimetallic switch |
|
|
ASI-11006 |
|
| |
i) Operation Range: Audio frequency (2KHz-8KHz), |
| |
ii) Power amplifier: 1 W capacity as a vibration generator , |
| |
iii) Piezo electric sensor |
| |
iv) Determination of aceleration (velocity, displacement
components. |
|
|
| |
i) Preheated thermister =100 ohm, |
| |
ii) DC fan (12V,1 1/2") to generate variable airflow in a mini wind tunnel with manual outlet ontrol, |
| |
iii) Bridge amplifier to O/P 0=2V at various temperatures (Fan speed) |
| |
iv) Determination of aceleration (velocity, displacement
components. |
|